A slim scanner for flat, rolled and half-palm impressions without bezel contact.

FASTfinger® MANNIX
Image resolution
500 PPI
Flat capture area
127 × 127 mm
Image quality standard
FBI Appendix F
Mobile ID acquisition profile
FAP 60
Palm capture on FASTfinger® MANNIX

FASTfinger® MANNIX captures single-, two- and four-finger flat impressions, single-finger rolled impressions and half-palm impressions at 500 PPI without requiring contact with the bezel.

The scanner is 20.3 mm thick. Its 127 × 127 mm sensing area is larger than the 81.2 × 50.8 mm area on FIVE-O, accommodating both finger and palm capture on the same device.

Features

500 PPI fingerprint and palm enrollment

FASTfinger® MANNIX is FBI Appendix F certified and meets FAP 60 requirements. It captures one, two or four flat fingerprints, a single-finger rolled impression, and separate upper and lower palm impressions at 500 PPI.

A slim scanner with room for a half palm

The 20.3 mm body houses a 127 × 127 mm sensing area, larger than FIVE-O’s. Rest the hand directly on the sensing surface to capture a half palm or the edge below the little finger (the writer’s palm), without touching a bezel.

Resistance to artificial fingerprints

The light emitting sensor (LES) records ridges through the electrical response of skin touching the film. Nonconductive replicas made of materials such as silicone or rubber do not activate the film.

Clear ridge detail on dry fingers

The LES film captures ridge detail even on dry fingers. The SDK can select a high-quality frame from the sequence, reducing the need for the operator to time each capture.

Less interference from latent prints

The film images the ridges while the finger is in contact. Marks left by the previous user have little effect on capture, reducing the need to wipe them away between successive enrollments.

USB host power for field use

A USB-C connection to a USB 3.0 host carries both data and power. At 5 V and 25 °C, a full scan draws 275 mA typically (about 1.38 W) and 320 mA at most. Standby draw is at most 40 mA.

Capture in sunlight or bright indoor light

The LES film emits light where the hand touches it, allowing finger and palm capture in direct sunlight or bright artificial light. The scanner emits no bright flash during capture.

A sensing surface without replaceable pads

The scanner requires no silicone membranes or cleaning tape. In shared use, the coated sensing surface can be cleaned and disinfected according to the manufacturer’s instructions.

Specifications

HardwareDimensions161 × 160.9 × 20.3 mm
Weight600 g (without cable or bumper case)
Current at 5 V, 25 °CFull scan (typical 275 mA, max. 320 mA) · standby (max. 40 mA)
Power calculated at 5 VFull scan (max. 1.60 W) · standby (max. 0.20 W)
USB host specificationGeneral specifications (manual p. 6): full scan < 500 mA. The current figures above are from the 5 V, 25 °C table on p. 7.
InterfaceUSB 3.0 (USB-C)
Image captureResolution500 PPI
Sensing area127 × 127 mm
Platen dimensions127.8 × 127.8 mm
Image size2500 × 2500 px
Capture frame rateFlat > 6 fps, rolled > 10 fps
Image standards and acquisition profile FBI Appendix F certified · Appendix P compliant
Mobile ID · FAP 60
Capture modesOne, two or four-finger flat impressions, single rolled finger, half palm